Vis enkel innførsel

dc.contributor.authorJarvis, Leighanne M.
dc.contributor.authorPeterson, Matthew J.
dc.contributor.authorCaves, Kevin M.
dc.date.accessioned2021-02-03T15:00:34Z
dc.date.available2021-02-03T15:00:34Z
dc.date.issued2020
dc.identifier.citationJarvis, L. M., Peterson, M. J., & Caves, K. M. (2020). Development, Validity, and Reliability of a Novel Walking Speed Measurement Device: the GaitBox. Gait & Posture.en_US
dc.identifier.urihttps://hdl.handle.net/11250/2726039
dc.description.abstractBackground Gait speed is an important measure of health status for older adults and individuals with neurological conditions. Literature reports that measurements made by people are not as accurate as automatic timers. Research question Is the GaitBox (GB), a device to measure walking speed (WS) automatically and accurately, a valid approach to walking speed measurement in a clinical setting? Methods Two prospective validation studies were completed comparing the GB to human timers (HT) and the Sprint Timing System (STS). Subjects were recruited from convenience samples of healthy older adults (S1, N = 35, 72.4 + 7.4 years of age) and individuals with Spinal Cord Injury (SCI), Traumatic Brain Injury (TBI), or unknown / no diagnosis (S2, N = 44, 35.3 + 13.5 years of age). Subjects completed 4 timed walks. The GB, HT, and STS simultaneously measured WS across a 4 m or 10 m course. Protocol followed an adapted version of the NIH Walk Test. Subjects were instructed to walk at a normal pace. Validity and reliability were determined using Pearson correlations, absolute mean differences, Intraclass Correlation Coefficients (ICC’s) and Bland-Altman plots. Results WS measured in both studies demonstrated strong correlations between GB and STS (r = 0.98-0.99, p < 0.0001), excellent test-retest reliability GB ICC’s (0.93-0.94), no systematic bias, and good precision. In S1 and S2, ICC’s between GB and STS were excellent at 0.91 and 0.93, respectively. Significance Considering the increased use of WS as a clinically relevant measure of mobility, functional decline, and recovery, accurate measurement of WS are important. These studies show the GB is a valid and reliable measurement tool within various populations completing the 4 m and 10 m walk tests at a usual speed. Additional populations and walking distances should be evaluated further. Due to its accuracy, the GaitBox is a valid alternative to HT in the clinic setting.en_US
dc.publisherGait & Postureen_US
dc.subjectwalking speeden_US
dc.subjectgaiten_US
dc.subjecttechnologyen_US
dc.subjectfunctional statusen_US
dc.subjectolder adultsen_US
dc.titleDevelopment, Validity, and Reliability of a Novel Walking Speed Measurement Device: the GaitBoxen_US
dc.typeJournal articleen_US
dc.source.pagenumber52-57en_US
dc.source.volume84en_US
dc.source.journalGait & Postureen_US
dc.identifier.doihttps://doi.org/10.1016/j.gaitpost.2020.11.009
dc.description.localcodemåsjekkes


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel